Request Proposal

  • Disinfection by-product compliance, CxT disinfection credits, iron & manganese removal, and taste and odor control
  • Maximum chlorine dioxide yield efficiency at 95%
  • Fail-safe mechanisms to ensure safe operation
  • Comply with NSF 61 standards for drinking water
  • Supported by Evoqua's best in class service team
Discontinued product
evoqa

Delivering safe, consistent, high-purity chlorine dioxide for disinfection and preoxidation

  • Disinfection by-product compliance, CxT disinfection credits, iron & manganese removal, and taste and odor control
  • Maximum chlorine dioxide yield efficiency at 95%
  • Fail-safe mechanisms to ensure safe operation
  • Comply with NSF 61 standards for drinking water
  • Supported by Evoqua's best in class service team
Discontinued product

Description

​The Millennium III™​ Chlorine Dioxide Generator is a safe and reliable solution for disinfection by-product compliance, CxT disinfection credits, iron & manganese removal, and taste and odor control. Concentrated chemical precursors are vacuum fed to safely control reactions, maximizing chlorine dioxide yield efficiency at 95 percent and minimizing by-product formation. Fail-safe mechanisms prevent chemical feed due to loss of motive water or vacuum, ensuring safe operation.

Millennium III generators comply with NSF 61 standards for drinking water applications and are easy to use and maintain. Evoqua’s best in class service ensures compliance and eliminates down-time.

Read how Chlorine dioxide is an effective solution for disinfection byproduct (DBP) control of TTHM's and HAA5's. This is evidenced in the "Study of the Formation and Control of Disinfection By-Products Originating from a Surface Water Supply on the Volcanic Island of Guam", a thesis authored by Erica LaBerge and published by the University of Central Florida. This study utilized an Evoqua chlorine dioxide generator and found that chlorine dioxide minimized DBP formation relative to alternative pre-oxidants. 

*LaBerge, Erica, "Study of the Formation and Control of Disinfection By-Products Originating from a Surface Water Supply on the Volcanic Island of Guam" (2014). Electronic Theses and Dissertations, 2004-2019. 4817

Read our AWWA Journal article on how chlorine dioxide is helping water treatment plants meet Stage 2 Disinfectants and Disinfection Byproducts Rule - Chlorine Dioxide Preoxidation for DBP Reduction.

Millennium III systems may be offered in a full-service solution which is backed by the industry’s most responsive service organization. Our technical experts can provide assistance with the design of a new system or aftermarket support of an existing site.

Working with your plant and process technical staff, our field sales and service personnel begin with a site and process evaluation to develop a full-service solution customized to your system and operational requirements. 

Learn how to effectively optimize the operation & performance of your system in our article, Implementing Chlorine Dioxide to Meet Drinking Water Compliance. 

Features

Configurations

​The Millennium III™ Chlorine Dioxide generators are available in the following configurations, utilizing either 2-chemical or *3-chemical reaction chemistries:

  • Manual
  • Batch
  • Automatic
*3-chemical systems can be designed to accommodate 12.5% sodium hypochlorite or 0.8% on-site electrolytic-generated bleach. For more information on electrolytic-bleach generators, please see our OSEC® Hypochlorite Generation Systems.

Features

  • State-of-the-art control valves specifically designed for low flow control of precursor chemicals
  • Flow controls include PID loop for sodium chlorite
  • Touch screen interface allows for maximum performance, ease in set up, parameter changes and troubleshooting
  • Real time generator effluent analysis using an in-line (full flow) chlorine dioxide analyzer allows self-tuning and performance display

Applications

  • Primary and secondary disinfection for drinking water treatment
  • Pre-treatment for oxidation and removal of Iron & Manganese
  • Control of slime, algae, bacteria, viruses and protozoa, including Giardia, Cryptosporidium and Legionella
  • THM / THAA control (DBP reduction) without the formation of bromate 
  • Taste and odor control
  • Biofilm & Nitrification control
  • Mollusk control
  • Others